翻訳と辞書
Words near each other
・ Bloemfontein railway station
・ Bloemfontein Young Tigers
・ Bloemhoek Dam
・ Bloemhof
・ Bloemhof Commando
・ Bloemhof Dam
・ Bloemhof, Rotterdam
・ Bloemkamp Abbey
・ Bloemside
・ Blofeld (disambiguation)
・ Blofib
・ Blofield
・ Blockdot
・ Blocked (video game)
・ Blocked call
Blocked rotor test
・ Blocker
・ Blocker (ice hockey)
・ Blocker (surname)
・ Blocker corporation
・ Blocker Gundan 4 Machine Blaster
・ Blocker House
・ Blocker House (Edgefield, South Carolina)
・ Blocker, Oklahoma
・ Blockfield
・ Blockführer
・ Blockhaus
・ Blockhaus d'Éperlecques
・ Blockhead
・ Blockhead (computer system)


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

Blocked rotor test : ウィキペディア英語版
Blocked rotor test
A blocked rotor test is conducted on an induction motor. It is also known as short circuit test, locked rotor test or stalled torque test.〔(【引用サイトリンク】title =Motor testing methods )〕 From this test, short circuit current at normal voltage, power factor on short circuit, total leakage reactance, and starting torque of the motor can be found.〔(【引用サイトリンク】title =Blocked rotor test )〕 The test is conducted at low voltage because if the applied voltage was normal voltage then the current through the stator windings would be high enough to overheat the windings and damage them.〔(【引用サイトリンク】title =Motor testing methods )〕 The ''blocked rotor torque test'' is not performed on wound-rotor motors because the starting torque can be varied as desired. However, a ''blocked rotor current test'' is conducted on squirrel cage rotor motors.
==Method==
In the blocked rotor test, the rotor is locked.〔(【引用サイトリンク】title =Blocked rotor test )〕 A low voltage is applied on the stator terminals so that there is full load current in the stator winding, and the current, voltage and power input are measured at that point. When the rotor is stationary, the slip, s = 1 . The test is conducted at 1/4 the rated frequency as recommended by IEEE, because the rotor's effective resistance at low frequency may differ at high frequency. The test can be repeated for different values of voltage to ensure the values obtained are consistent. As the current through the stator may exceed the rated current, the test should be conducted quickly.〔(【引用サイトリンク】title =Motor testing methods )〕 By using the parameters found by this test, the motor circle diagram can be constructed.

抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)
ウィキペディアで「Blocked rotor test」の詳細全文を読む



スポンサード リンク
翻訳と辞書 : 翻訳のためのインターネットリソース

Copyright(C) kotoba.ne.jp 1997-2016. All Rights Reserved.